12 | Starting up the Tronic 3000C Pro
5.3
Appendix Flow vs. Temperature Setting Guide
The following graph Indicates the water temperatures the
Thermostatic Tronic 3000C Pro can achieve at different flow
rates. The graph shows the maximum and minimum
Fig. 8
As water temperature varies throughout the
year adjustments to the Temperature
Adjustment Spindle and/or the flow rate may
be required.
We recommend setting the temperature
adjustment spindle to the maximum setting.
(see graph above).
If necessary, adjust the outlet service valve
until the water comes out of the tap at the
desired temperature (increase flow for
cooler water, decrease flow for hotter
water). The heater will then maintain the set
temperature in the summer months
reducing the power automatically.
6 720 647 088 (2017/05)
temperatures achievable for the 12 kW unit with an inlet water
temperature of 50°.
When inlet water temperature increases
during the summer months, the heater will
maintain set temperature by reducing the
power automatically. In cases of extremely
warm incoming water supply, open service
valves fully to ensure maximum flow through
the unit.