▶ Connect the cables to the terminal block and ground stud
(Fig. 3 ):
Fig. 3
Cable termination
[1] Ground
[2] Rubber sleeve
4.5

Securing the unit to the wall

4.5.1 Deciding the position

▶ If being used in a public place, position the unit out of reach
to discourage vandalism.
▶ Mount the unit onto a flat section of wall, well away from
any potential splashes of water or spray.
▶ Position the unit as shown (Fig. 4 ).
Remember to keep the length of hot water pipe to a
minimum in order to save energy.
▶ If the unit is to supply a sink, you can It it either above or
below the sink.
WARNING:
▶ Unit must be mounted as shown in Fig.
4 with plumbing connection on the
bottom. Under no circumstances should
the unit be mounted differently.
Tronic 3000 C Pro
NOTICE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non grounded
conductors must be provided that is within
sight of the appliance. (REF NEC 422.31).
▶ Make sure that all the terminal block screws are tightened
securely. Loose connections can cause wires to neat up.
▶ Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut should be
tightened securely.
▶ Attach the front cover and tighten the retaining screws.
Installation | 9
6 720 647 088 (2017/05)