Technical Manual & Parts Lists
1961-PPAR4 Parameter Settings
Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
111
400-9900
119
153
161
161
220
270
272
015-9999
436
401
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off
LED 6: Off
LED 7: Off, Stop at needle down.
LED 8: Off
*Set sewing speed at 5000 and puller speed to 800 for first 90 days of operation
and then increase to 6000 and 1000 if desired.
27
VALUE
0
0-5
0
800/1000* Maximum speed when "129" is 0, 1, or 2. **
1-3
1
0-50
35
0-1
1-CCW
0-1
0-CW
1-55
5
0-5
5
240
0
0
1
1961 PARAMETER SETTINGS FOR PULLER MOTOR
Mode of operation. MUST SET THIS PARAMETER FIRST!
F-026=0 to disable the EB401 selection after power on.
Linear acceleration
Braking power at standstill
Motor rotation
Motor rotation for worm drive pullers
Acceleration
No handwheel sensor
Drive ratio for worm drive pullers. (current model)
(Older belt drive pullers should be set on 1000)
The smaller the number the higher the speed
Use code "5913". This disables an input that was causing box to
reset itself.
Change 401 from 0 to 1 to save all parameters
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "3112"
3. Press "E" once and "2.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
DESCRIPTION