1961-RPAR4 Parameter Settings
Before Programming, Perform a Master Reset of Parameters (See Below)
PARAMETER
RANGE
290
026
111
200-9900 rpm
119
161
270
272
015-9999
436
401
Front panel LED's:
LED 1: Off
LED 2: Off
LED 3: Off
LED 4: Off
LED 5: Off, Stop at needle down.
LED 6: On, Stop at needle up.
LED 7: Off
LED 8: Off
NOTE: Set sewing speed at 5000 and puller speed to 800 for first 90 days of operation
and then increase to 6000 and 1000 if desired.
VALUE
0
Mode of operation. MUST SET THIS PARAMETER FIRST!
0-5
0
F-026=0 to disable the EB401 selection after power on.
5000/6000 Maximum speed when "129" is 0, 1, or 2.
1-3
1
Linear acceleration
0-1
0=CW
Motor rotation
0-5
1
External handwheel sensor configuration.
Drive ratio between motor pulley and handwheel pulley. If handwheel
pulley is smaller than motor pulley, increase this value to slow down
1000
sewing head until measured speed matches speed set with
parameter 111. (For Yamato and Pegasus, setting should be 1000;
for Rimoldi, setting should be 1240)
Use code "5913". This disables an input that was causing box to
0
reset itself.
0
1
Change 401 from 0 to 1 to save all parameters
Programming Instructions:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "3121"
3. Press "E" once and "4.0.0." is displayed this is a parameter
4. Proceed to the parameter to be changed and press "E"
5. The value now shows in the screen, adjust to desired value.
6. Press "E" to enter value and continue with parameter setting.
7. Repeat for other parameters, press "P" once when complete.
8. Run sewing head to save parameters before powering down
To Perform Master Reset of Parameters:
1. Power on holding down the "P" button till "COD" is displayed.
2. Press ">>" once and enter the number "5913"
3. Press "E" twice and "093" is displayed.
4. Press "+" once, "094" is displayed.
5. Press "P" to exit programming mode with all default values.
Technical Manual & Parts Lists
DESCRIPTION
28