Cleaning and maintaining the machine
6.4 Lubricate the crimping unit
Potential risk of fatality due to electric
shock!
When working on the inside of the machine,
non-insulated parts may be touched.
► Switch the machine off.
► First remove the compressed air hose
from the compressed air source, then from
the maintenance unit.
► Pull the power plug.
► Remove the four mounting screws of the housing.
► Lift the housing upwards.
► Disconnect the ground wire from the housing.
2
3
4
► Lubricate the crimp wedge (1) with grease on all sides.
► Lubricate all rollers (2), pivot points (3) and sliding sur-
faces (4).
► Reconnect the ground wire to the housing.
► Replace the housing.
► Tighten all four fixing screws.
18
WARNING
6.5 Servicing the compressed air mainte-
nance unit
Risk of injury posed by electrical volt-
age!
► Make sure that the machine is switched off
and the mains plug has been pulled.
Risk of injury posed by compressed air
hoses swinging around!
► Make sure that the compressed air hose
is disconnected from the compressed air
source.
1
3
2
1
Figure 6.2 Compressed air maintenance unit
As required
► To drain the condensate press the drain plug (1) up-
wards.
► To change the filter, unscrew the condensate tank (2)
and screw off the filter (3).
► Insert a new filter and screw the condensate tank back
on tightly.