Gear Housing - Flex XFE 7-15 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

XFE 7-15 / XCE 10-8
Brush inspection and lubrication
For your continued safety and electrical
protection, brush inspection and
replacement on this tool should ONLY be
performed by an authorized service center
for FLEX Power Tools.
At approximately 100 hours of use, take or
send your tool to your nearest authorized
service center for FLEX Power Tools to be
thoroughly cleaned and inspected; worn
parts replaced; and when necessary,
relubricated with fresh lubricant if required;
reassembled with new brushes; and
performance tested.
Any loss of power before the above
maintenance check may indicate the need
for immediate servicing of your tool.
DO NOT CONTINUE TO OPERATE TOOL
UNDER THIS CONDITION.
lf proper operating voltage is present, return
your tool to a FLEX authorized service
center for immediate service.

Gear housing

The gear housing (2) should never be
loosened or opened, except by a FLEX
authorized service center. Doing so will void
the product warranty.
Change Velcro pad
– Pull out the mains plug.
– Remove the polishing tool.
– Place machine on its back.
– Release and remove screws with Torx
wrench (1.).
– Remove worn Velcro pad (2.).
– Remove contaminants from interior.
– Align securing holes and fit new Velcro
pad (3.).
– Insert screws and tighten with Torx
wrench (4.). (Tightening torque 2.5-3.0 Nm
(1.8-2.2 ft. lb.))
– Carry out test run. Check for imbalances
and vibrations.
CAUTION
An incorrect torque setting can damage
the tool and the surfaces being worked on.
Instruction manual
13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Xce 10-8

Tabla de contenido