TDB3104, WF3204
Adaptive infrared assembly for A drain and O drain units
5a
without Tie Pipe option continued...
Place the infrared module assembly on top of
D
sprayhead. Rotate until infrared module locks in
with tie bar. Drop two infrared module wires down
the support tube. Make sure infrared module
windows are facing away from the wall.
Skip to step F for units without soap.
For units with soap option, install the spacer, soap
E
dispenser and cover using the third tie rod (8-5/8"
long) and second coupling nut as shown. Secure
with acorn nut and set screw.
Secure infrared module cover and top cover with
F
sprayhead restraining bracket, acorn nut and set
screw.
G
Connect supply stops onto stub-outs. Connect
flexible hoses to supply stops.
12
1/15/2013
Unit with "A" Drain and IR Module Shown,
Also Available with "O" Drain
Restraining Bracket
(140-126)
Soap
Dispenser
Coupling
Nut
Coupling
Nut
Tie Rod
STD 21-5/8"
Juv 18-1/8"
Support Tube
Standard (S57-005)
Tas/Juv (S57-006)
Bradley • 215-1078 Rev. T; ECN 12-00-004
Installation
Top
Cover
8-5/8" Tie Rod
Spacer
Module
Cover
4-1/4" Tie Rod
IR Module
Assembly
(S50-367)
Tie Bar
Sprayhead
(S05-054B)