Installation
Read this entire installation manual to ensure proper installation. When finished with the
Installation
installation, file this manual with the owner or maintenance department.
Separate parts from packaging and make sure all parts are accounted for before discarding
Packing List
any packaging material. If any parts are missing, do not begin installation until you obtain
IS
the missing parts.
T H
E
S ID
U P
Make sure that all water supply lines have been flushed and then completely turned off
before beginning installation. Debris in supply lines can cause valves to malfunction.
Hardware supplied by installer must be appropriate for wall construction. Wall anchors used
must have a minimum pull-out rating of 1,000 lbs.
The Adaptive
Connections to 110 VAC can cause personal injury and will result in damage to the
electronics.
Product warranties may be found under "Product Information" on our web site
at www.bradleycorp.com.
Supplies Required by Installer
• (4) 1/2" lag bolts, screws or other fasteners to anchor washfountain pedestal
• 1/2" nominal copper tubing for hot and cold water supply lines.
• Standard P-trap (vented trap supplied by Bradley when required)
• 2" drain lines and fittings
• 1-1/2" vent or tie pipe on fixtures vented through washfountain column
• Teflon tape or pipe dope
• 110 VAC GFI power source for 110/24 VAC UL Class II transformer supplied
• OPTIONAL: Bradley recommends installing an electrical cut off switch to the unit. This feature allows no accidental
water delivery during regular maintenance and service.

Pre-Installation Information

Terreon
Material
®
The Washfountain is constructed of Terreon
chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleaners or fine-grit abrasives. Terreon
is NAHB certified to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001.
Adaptive Infrared
The sprayhead is controlled by a solenoid valve, allowing the user to activate a flow of water. The Infrared sensor will take a few
minutes to adapt to its environment when the unit is powered up.
Bradley • 215-1078 Rev. T; ECN 12-00-004

IMPORTANT!

Infrared control must be connected with a 24 VAC Class II transformer.
®
, a densified solid surface material composed of polyester resin. Terreon is resistant to
®
TDB3104, WF3204