8. Prepare the camera for inspection. The
camera cable may need to be pre-formed
or bent to properly inspect the area. Do
not try to form bends less than 2" radius.
This can damage cable. If inspecting a
dark space, turn the LEDs on before in-
serting the camera or cable.
Do not use excessive force to insert or
withdraw the cable. This may result in
damage to the electrical device or in-
spection area. Do not use the cable or
imager head to modify surroundings,
clear pathways or clogged areas, or as
anything other than an inspection de-
vice. This may result in damage to the
electrical device or inspection area. Do
not insert the camera or cable into any
space that will require less than a 2"
bend radius. Tight bends could damage
the cable.
9. When the inspection is complete, care-
fully withdraw the camera and cable from
the inspection area.
Controls
Back – Pressing the
back button at any time
will take you to the last
viewed screen.
Shutter – Pressing shut-
ter button will take a still
image or start and stop
the video recorder.
microEXPLORER
Figure 10 – Controls
Ridge Tool Company
™
Digital Inspection Camera
10. Remove the batteries and refer servicing
to qualified service personnel under any
of the following conditions.
• If liquid has been spilled or objects have
fallen into product.
• If product does not operate normally
by following the operating instructions.
• If the product has been dropped or dam-
aged in any way.
• When the product exhibits a distinct
change in performance.
Trash – Pressing the trash
button while in the playback
screen will delete an image
or video.
Select – Pressing select
while in live screen will
take you to the primary
settings screen.
Arrows – Use the arrow
buttons to navigate
through menus, operate
LEDs, zoom and pan.
9