Connections & Installation
A Multi-Drop Communication System
A system that employs the RM-P2580 as the controller
The following figure shows a system that can accommodate up to eight cameras. (64 positions can be preset per camera.)
TK-C676
Camera 1
MACHINE ID: 01
Switch 8: OFF
(RX TERM)
TK-C676
Camera 2
MACHINE ID: 02
Switch 8: OFF
(RX TERM)
TK-C676
Camera 8
MACHINE ID: 08
Switch 8: ON
(RX TERM)
Remote control unit
Cable connections
(Terminal side of Ceiling Mount)
Control signal cable
Coaxial cable
Power cable
Connection of the control signal cable
(A twisted pair cable is recommended.)
RM-P2580
Camera 1
CONTROL terminals
terminal
TX + A
RX +
A
TX – B
RX –
B
RX + C
TX +
C
RX – D
TX –
D
Camera 2
CONTROL
terminals
TX +
A
Each terminal on the camera and the RM-
TX – B
RX + C
P2580 is marked
RX – D
to facilitate understanding and to avoid
Camera 3
connection mistakes, it is recommended
CONTROL
terminals
to connect the terminals carrying the
TX + A
same marks.
TX – B
RX + C
RX – D
E-8
Control signal cable
Coaxial cable
AC 24 V
power supply
AC 24 V
power supply
AC 24 V
power supply
TO
CAMERA
RM-P2580
P. 14
To the TO CAMERA connector of the
RM-P2580 and to the next camera
To the CAMERA INPUT connector
of the RM-P2580
To AC 24V power supply
,
,
or
. In order
A
B
C
D
Observe the following points when connecting compo-
nents together:
• Turn all the components off before proceeding.
• Read the instruction manuals of all components before pro-
ceeding.
• For the types and lengths of connection cables, see "Cable
Connections" on page 14.
• Do not connect the control signal cables in a loop.
MONITOR
OUTPUT 1
Switch settings
(Setting switches are on the side of the Ceiling Mount)
Machine ID
Figure of 1
Figure of 10
Set it to the same number as the
VIDEO INPUT terminal of the RM-
P2580.
(Example) Camera 1:
Set the figure of 10 to "0" and
figure of 1 to "1".
Camera 1 monitor display
at power ON
>> I I
N T I A
L PROCESS<<
PAN
: - - I - -
T I LT
: - - I - -
>P
ROT
O OL
C
DUPLEX I D - 01
Duplex display
ID No. display
(ID check procedure
P. 13)
Monitor
P. 12
Switch 1 :
Invalid (Set to OFF.)
Switch 2 :
Switch 4 : ON
Switch 5 : OFF
Switch 7 : Invalid (Set to OFF.)
Switch 8 :
Set to ON only for the
camera connected at
the end of the control
signal cable.
Set to OFF for all