6.2.4 Description of the user interface (Fig. 4)
Manual operating
Operating mode
auto
Hand/Auto
Menu
Enter
Value setting up
Value setting down
6.2.5 Description of the electronic board (Fig. 5)
1. Input terminal of the ElectronicControl.
2. Input terminal of the motor.
3. Protection fuse of the ElectronicControl input
(I: 20A, type: gG, U: 500Vac, breaking capacity I1:
120kA, size: 10 x 38mm).
4. Protection fuse of the motor input (I: 20A, type:
high speed, U: 690Vac, breaking capacity I1:
100kA, size: 10 x 38mm).
6.2.6 Diameter of the manifolds
COE 2-EMHIL series 3/5 m
6.2.7 Lack of water protection
The booster needs to be fitted with a dry-run-
ning protection device:
• Connection to public water supply: pressure
switch to be assembled on the suction manifold
and connected to the ElectronicControl.
• Connection to a tank: float switch to be installed
on the tank and connected to the
ElectronicControl.
6.3 Product function
6.3.1 Operating
The automatism of system is ensure by
ElectronicControl. 1 pump is set to Master for
the other.
ElectronicControl contains an electronic regula-
tion system using pressure and flow sensors and
a frequency inverter.
The electronic regulation system allows to reach
a constant pressure in the network whatever the
flow is and to minimize the power consumption
of the installation (automatic mode). The pres-
sure will be constant according to the set point
pressure originally preset.
In hand mode the pump can be tested at maxi-
mum speed.
In automatic mode the ElectronicControl starts
the pump when the installation pressure (NET P)
is lower than the set point pressure (P SET)
minus the pressure gap set (START DELTA P).
The ElectronicControl stops after a time period
set (TIME BEFORE STOP) when the installation
pressure (NET P) has reached the set point pres-
sure (P SET) and when the flow is zero.
6
auto
3
/h: threaded manifolds 2"
ElectronicControl
Green led
ON
Blinking : current error
Red led
Fix
Yellow led
Pump is working
ON
: Automatic mode
Green led
OFF
: Manual mode
The ElectronicControl protects the pump against
(§ 10.2):
- dry running,
- over currents,
- too high water temperatures,
- frost,
- short-circuits,
- over voltages,
- Under voltages.
In case of defect (such as dry running, overvolta-
ge ...), the led
blinks and the
ElectronicControl will try to start the pump regu-
larly. After many trials the ElectronicControl
finally stops and the led
blink anymore.
6.3.2 ElectronicControl setting
After connection to the pump and to the power
supply, the ElectronicControl will show the
model type and the version for 10 seconds. Then
it shows the STANDARD display mode.
Then the ElectronicControl has to be set in
accordance to the pump characteristics and to
the requirement of the installation, in order to
warranty a safe and efficient operation.
Press the push-button
the ElectronicControl. The user can navigate in
both menu levels, SETTINGS or HISTORIC:
• SETTINGS: this level allows the setting of the
ElectronicControl according to the installation
and the pump.
• HISTORIC: this level displays the various counts
and alarms recorded.
To select a menu level, use the the
push-buttons
or
select it.
The values displayed in the various menus can be
changed via the push-buttons
the push-button
validated and the next menu is displayed on the
screen. With the push-button
TINGS (no saving of the last change) or HISTORIC
menu and go back to STANDARD display mode
(or SERVICE).
NOTA: the data are saved in non-volatile memo-
ry, this allows to save data even after switching
off.
: final error
is ON but does not
for 3 seconds to set
, then push
to
or
. With
the new value selected is
you exit SET-
WILO SE 04/2013