Setting Menu - Wilo COE-2-EMHIL Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28

6.3.3 Setting menu

Display
NET P
P SET
02.0 bar
02.0 bar
F
PREF
PRES
Q
50
02.0
02.0
1
MENU
LANGUAGE
ENGLISH
I MAX PUMP
OFF
ROTATION SENSE
0
HZ
MIN SPEED
30 HZ
DRY RUN PROT
NO
PRESSURE SETTING
2.0 BAR
START DELTA P
0.3 BAR
TIME BEFORE STOP
5 S
STANDARD
DISPLAY
RUNNING TIME
HOURS
26h
PUMP CYCLES
30
POWER ON
30
MAX PRESSURE
0.0 bar
ALARM COUNT
SHT CIRCUIT
15
ALARM COUNT
OV CURRENT
10
ALARM COUNT
OVERT T°
5
ALARM COUNT
DRY RUN
6
WILO SE 04/2013
Menu Level 1
Menu Level 2
SETTINGS
LANGUAGE
I MAX PUMP
ROTATION SENSE
MIN SPEED
DRY RUN PROT
PRESSURE SETTING
START DELTA P
TIME BEFORE STOP
DISPLAY
HISTORIC
RUNNING TIME
PUMP CYCLES
POWER ON
MAX PRESSURE
ALARM COUNT
SHT CIRCUIT
ALARM COUNT
OV CURRENT
ALARM COUNT
OVERT T°
ALARM COUNT
DRY RUN
Description
Display in STANDARD mode
Display in SERVICE mode
Language setting
Nominal current setting as mentioned on the
identification plate of the pump.
Setting of the rotation sense. See the pump
identification plate. Push on
pump (at 30hz) and check the rotation sense.
Define the minimum motor rotation speed.
If the installation is provided with a level switch
(flow switch or other ones) change No by Yes.
Working pressure setting in the installation.
Define the starting pressure as: starting pressure
= setpoint pressure – start delta P
Time setting before pump stop when there is no
flow.
Define the display mode:
- STANDARD: pressure setting (bar) + network
pressure (bar)
- SERVICE: rotation frequency (Hz) + pressure
setting (bar) + networkpressure (bar) + flow
switch detection (1 or 0)
Total pump running hours (H).
Total number of pump cycles, one cycle includes
one start and one stop.
Number of ElectronicControl switching on.
Storage of the maximum pressure reached in the
installation (bar).
Total number of short circuits.
Total number of overcurrents.
Total number of exceeding temperatures.
Number of dry running Only internal detection
no counter for external detection
English
to start the
7

Publicidad

Tabla de contenido
loading

Tabla de contenido