2.1 Rear panel interface introduction:
No.
Name
1
PTZ-CON
2
PTZ-AUX
3
Ground
4
DVR-AUX
5
DVR-CON
6
7
8
9
DC-12V
Note: The loop function (DVR-AUX/PTZ-AUX) is used to manage multiple controllers, so that only
one signal will control the PTZ or the DVR from the DVR/PTZ-CON on that same
controller, the C06 controller connected to the PTZ/DVR will overrule other conflicting
orders. That means that a PTZ camera will be connected to one C06 keyboard that will
manage the network of multiple RS485 controllers by priority of proximity. Please note
that some cameras will not work without a loop gateway because conflicting orders
may harm the PTZ camera.
Important: all connections must be made before plugging the equipment to the electricity. Do not
use RS485 cable longer than 1200 meters to and from the C06 keyboard.
keyboard connection to directly control PTZ cameras;
Loop from other controllers/DVRs to control PTZ cameras;
Ground control for signal line terminal
Loop from other C06 keyboards to control DVRs;
keyboard connection to directly control DVRs;
PTZ
When in PTZ mode the green led will blink
DVR
When in DVR control mode the green led will blink
PW
Power indication will be red when the keyboard is on
Power input (DC-12V) DC 12V power input
Description
Ta is RS485+
Tb is RS485-
Ra is RS485+
Rb is RS485-
Ra is RS485+
Rb is RS485-
Ta is RS485+
Tb is RS485-
| P a g e
4