Keep sufficient distance between the appli-
ance and combustible materials such as
wooden walls and furniture.
The connecting tube also radiates heat. Ensure
that there is sufficient distance or a shield
between the connecting tube and combustible
material.
The rule of thumb for a single-walled tube is a
distance of 3x the diameter. If a lining shell is
fitted around the tube, a distance of 1x the dia-
meter is permissible.
Carpets and rugs must be at least 80 cm away
from the fire.
Use a fireproof floor plate to protect a flam-
mable floor from any ash that may fall in front
of the stove. The floor plate must comply with
national standards.
For the dimensions of the fireproof protective
plate: see the appendix "Distance from com-
bustible material".
For further requirements with respect to fire
safety, see the appendix "Distance from com-
bustible material".
8
Product description
5
7
3
4
1
6
2
8
1. Door
2. Latch
3. Stove base
4. Fire basket
5. Flue gas connection
6. Primary air slide
7. Secondary air slide (glass wash)
8. Leg
Subject to change because of technical improvements