1. Loosen the connection between the damper and
the damper rod by loosening the connecting
screw.
2. Loosen the connection between the connection
collar and the smoke dome by unscrewing the two
M8 nuts. The damper rod now comes off the
appliance.
3. Turn out the screws at the bottom of the appliance
whereby the damper rod is fastened to the
appliance.
4. remove the damper and the damper rod.
Take care not to drop the damper into the
appliance when removing the damper rod.
5. Lift the connection collar from the two bolts.
6. Rotate the connection collar 180° and put the
connection collar back onto the smoke dome.
7. Put back the damper and the damper rod and
tighten the screw whereby the damper rod is
fastened to the appliance.
8. Connect the connection collar to the smoke dome
by tightening the two M8 nuts.
9. Use stove sealant as a seal between the
connection collar and the smoke dome.
The stove sealant is not supplied with the
appliance.
Fitting the side panels (model
2180CBGD only)
Model 2180CBGD is supplied with two side panels to
cover the runners of the guiding system on the left and
the right sides.
1. Put the top of the side panel (A) into the slot (B) at
the top of the appliance; see next figure.
10
2. Push the bottom of the side panel against the
appliance. The panel is kept in position by a
magnet; see next figure.
Subject to change because of technical improvements