Technical Information
Deleting limit position(s)
With this button you delete one or both limit positions.
Both limit positions must be set before deleting.
After activation, the settings button will flash, the tubular drive will click twice to confirm
and the signal lamp will flash twice.
If the tubular drive is situated between the limit positions, both limit positions are deleted.
Depending on the version of the tubular drive, when a limit position is reached, one or both
limit positions are deleted.
Setting the limit positions (point)
With this button, you set a limit position (point). Ensure that no point has already been set
in the desired limit position.
After activation, the settings button will flash, the tubular drive will click once to confirm and
the signal lamp will flash once.
Depending on the version of the tubular drive, when a limit position is reached, this limit
position is deleted. Press the button once more in order to re-set a point.
Activating/deactivating the anti-freeze mechanism
Please check whether the version of the tubular drive supports this functionality.
With this button you can activate or deactivate the anti-freeze mechanism at the top. To do
so, the tubular drive must be located in the upper end position.
Press the SET button for 10 seconds. The tubular drive clicks 3 times and the signal lamp
flashes 3 times to confirm.
Wired/radio switching
The settings button lights up in wired mode and flashes in radio mode.
Operating and setting via the transmitter is only possible in radio mode.
If necessary, further functions can be programmed via the transmitter in radio mode.
Deleting the transmitter (incl. the master transmitter)
Press the SET button for 10 seconds. The tubular drive clicks once and the signal lamp
flashes once to confirm.