Characteristics
Input Parameters
Nominal PV power [kWp]
Total (master/slave mode)
Absolute maximum input voltage [Vdc]
MPPT input voltage range [Vdc]
Multi-master configuration
Multi-master/slave configuration
Master/slave
Total Maximum input current [Adc]
Multi-master mode (each module)
Input Reflected Ripple voltage
Number of DC inputs
Max. DC input wire (each polarity)(reduced terminal size)
Standard Equipment - Input
Insulation Control
Reverse polarity and backfeed current protection (each input)
Input fuse overcurrent protection (no for Multi-Master cof.)
Load-breaking internal DC switch
Input overvoltage protection
Output Parameters
Nominal AC Output Power, PACnom [up to 50°C, kW]
Nominal AC Output Current [Arms]
AC Output Voltage range [Vrms]
Nominal AC Frequency [Hz]
Nominal Power Factor / adjustment range [cos φ]
AC Current Harmonics [THD%]
Inverter Switching Frequency [kHz]
Max AC output wire section (each phase)
Standard Equipment – Output
AC Contactor (night time disconnect)
AC Output Circuit Breaker (Magnetothermic switch) / Breaking capacity [kA]
(*) 300Vac side of the transformer
AC side overvoltage protection (power and aux input)
Conversion Efficiency @ Vdc=485V and Vac=320Vrms
Peak Efficiency %
Euro Efficiency %
CEC Efficiency %
Environmental Parameters
Environmental Protection Degree (acc to EN 60529)
Operating Temperature Range with output power derating
Required ambient air cooling flow
Relative Humidity (non-condending)
Maximum altitude above sea level without derating [mt]
Audible Noise [dBA @ 1mt]
Auxiliary Supply
External Auxlilary Supply Voltage
Maximum consumption in operation
Maximum consumption in operation (ac-box fan off)
Night time losses [W]
Communication/User Interface
Communication Port (PC / Datalogger)
Communication - String Combiner boxes
Remote Communication (optional)
User Interface
Mechanical Characteristics
Dimensions (WxHxD) [mm]
(*) Output Air conduit not included
Overall Weight [kg]
55kW module Weight [kg]
Tabla 21-1: Datos técnicos PVI-55.0(-TL)
PVI-55.0
56,4
59
1000
485 - 850
1
na
1
123
123
<3%
1
1x185mmq (M10)
Yes, with alarm
YES, with series diode
125A/1000V
200A/1000V
Yes
55
81
3 x 400 +/-15%
50 / 60
1 / -0,95...+0,95 (@ Pac nominal)
< 4% (@ Pac nominal)
18
1x95mmq (M8)
Yes
Yes / 50kA
Yes
96,30%
95,10%
95,80%
IP20
-10°C...+60°C
1500m3/h
< 95%
1000
<62
3x400Vac + N, 50/60Hz
<0.36% PACnom
<0.25% PACnom
<17W
1 x RS485 (RS485_USR)
1 x RS485 (RS485_2)
WEBLOGGER (Ethernet, GPRS)
2-lines Display
1250 x 1607(*) x 893.5
800
60
Página 149 de 157
PVI-55.0-TL
56,4
59
1000
485 - 850
1
na
1
123
123
<3%
1
1x185mmq (M10)
Yes, with alarm
YES, with series diode
125A/1000V
200A/1000V
Yes
55
101
3 x 320 +/-20%
50 / 60
1 / -0,95...+0,95 (@ Pac nominal)
< 4% (@ Pac nominal)
18
2x300mmq (M12)
No
Yes / 50kA
Yes
98,00%
97,71%
97,78%
IP20
-10°C...+60°C
1500m3/h
< 95%
1000
<60
3x400Vac + N, 50/60Hz
<0.24% PACnom
<0.22% PACnom
<12W
1 x RS485 (RS485_USR)
1 x RS485 (RS485_2)
WEBLOGGER (Ethernet, GPRS)
2-lines Display
1250 x 1077(*) x 893.5
380
60