INSTALLATION - TECHNICAL ADVICE
Before connection, please consult the following points:
BATTERY
has an automatic voltage detection. For its correct functioning, please check:
UNIMPPT
- If the battery voltage is higher than 6V (required voltage for the startup of the solar charge controller)
- For 24V batteries, the voltage cannot be lower than 18V.
For flooded batteries, check the electrolyte level. If necessary, complete before charging.
For coupling, proceed as follows:
In series
Some extra advice:
In
case
of
parallel
connection,
favour
diagonal wiring for a
standardization of the
charge/discharge
Prefer a high-capacity
battery to 2 smalls
connected in parallel,
for equal capacity
In parallel
Do
batteries
different
different
different technologies
www.uniteck.fr
In series and in parallel
not
couple
with
capacities,
age
or
EN
25/55