EN
ALGOTECK CHARGING CURVE
BATTERY CHARGING STEPS
The ALGOTECH charging algorithm, unique on the market, is composed of 6 steps.
1
2
3
4
5
6
Voltage threshold
Boost
Equalisation
Recond.
Floating
Nb: the voltage levels above are ajusted to ALGOTECK conditions
32/55
TEST
BOOST CHARGE
(I)
EQUALISATION
(max. 4 hours)
RECOND.
100%
LIFE+/
STORAGE
UNIMPPT determines on a daily basis the health status and
charging status of your battery and determines the steps
and charging levels required for the maintenance of your
UNIMPPT uses 100% of the energy from the solar panel,
until the voltage reaches the equalization level. The
battery is charged at 80%.
UNIMPPT equalises the charge on all battery elements
(battery charged at 100%)
Only in liquid mode, this step stirs, thanks a pulsed current,
the electrolyte of your battery to avoid all stratification or
sulfation phenomena.
The battery charge is done. The green "load" light starts
blinking. UNIMPPT continues to deliver a low current to
compensate the battery's self-discharge.
UNIMPPT compensates the battery's natural self discharge,
with a pulse charge for a longer battery lifespan.
Gel
14,2 V
-
-
13,9V
www.uniteck.fr
battery.
AGM
Liquid
14,4 V
14,5 V
14,4V
14,5V
-
14,8V
13,9V
13,9V