Remedy Of Faults - Oase ProMax MudDrain 25000 Instrucciones De Uso

Ocultar thumbs Ver también para ProMax MudDrain 25000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32

REMEDY OF FAULTS

W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocution.
Prior to starting work:
• Switch off the unit, disconnect the power plug and secure the unit from being switched
on again.
• Before stepping into or reaching into the water, switch off all units located in the water.
On completion of the work:
• Restore all the prerequisites for start-up.
Malfunction
Pump does not start.
Pump switches off after a
short running period.
The pump is running but is
not delivering, or the deliv-
ered quantity is insufficient
Cause
Power supply interrupted
Overload protection has
switched the pump off due
to overheating.
Pressure hose kinked
Intake blocked
Air in the pressure hose
If applicable:
Non-return valve incorrectly
fitted in the pressure hose
or clogged
Impeller defective or worn
Remedy
Check the fuse and electri-
cal plug connections.
• Clean the intake and
pressure hose.
• Allow the pump to cool
down.
• Route the pressure hose
without kinks
• Check the outlet and
clean if necessary
• Clean the intake
• Expel the air from the
pressure hose.
• Correctly fit the non-re-
turn valve.
• Clean the non-return
valve.
Contact OASE
• The impeller may only
be replaced by the
OASE Service.
DE
EN
FR
NL
ES
PT
IT
DA
NO
SV
FI
HU
PL
CS
SK
SL
HR
RO
BG
UK
RU
CN
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Promax muddrain 30000

Tabla de contenido