Product description
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
Al 99 %
CuZn 37
Cu
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
Al 99 %
CuZn 37
Cu
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
IN40-E0101K
Enable zone
Lower limit
Upper limit
10.0 mm
15.0 mm
7.5 mm
13.2 mm
2.0 mm
5.8 mm
1.4 mm
5.0 mm
2.3 mm
6.2 mm
0.8 mm
4.3 mm
IN40-E0109K
Enable zone
Lower limit
Upper limit
4.0 mm
20.0 mm
2.0 mm
17.6 mm
0.0 mm
9.6 mm
0.0 mm
8.6 mm
0.0 mm
10.0 mm
0.0 mm
7.0 mm
GB
Chapter 3
Safe
switch off
distance
30 mm
Safe
switch off
distance
45 mm