Mounting
The IN4000 Direct safety switch is only allowed to be
fitted by authorized specialist personnel.
Select the mounting location and the mounting position
for the safety switch such that
• it is difficult for operators to access the safety switch
when the protective device is open,
• it is possible to inspect and replace the safety
switch.
Bypassing the inductive safety switch using simple
means must, as per EN 1088, be prevented by
installation features.
4.1

Mounting of the safety switch

Pay attention to the stipulated mounting method and
the resulting classification as per EN 60 947-5-2!
Surrounding
material
Copper,
aluminium,
brass
Steel
Permissible mounting methods
IN40-E0101K
Flush
I1C40SP2
Flush on one
side
or
non-flush
I2C40SP2
Operating instructions
IN4000 Direct
IN40-E0109K
Non-flush
I2C40SP2