Indications In The Adjustment Mode - SICK Direct IN4000 Instrucciones De Servicio

Ocultar thumbs Ver también para Direct IN4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB
Chapter 3
Note
Tab. 3: Status
indicators of the
IN4000 Direct in
adjustment mode
The LED is
illuminated
constantly.
The LED is
flashing.
The LED is
flashing
quickly.
The LED is
off.
162
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Product description
3.4.2

Indications in the adjustment mode

In the adjustment mode (see section 5.2 on page 172)
• the yellow signal LED flashes when the actuating
element is outside the enable zone,
• the yellow signal LED extinguishes when the actuat-
ing element is within the enable zone or in the safe
switch off range.
The output remains in the safe state in the adjustment
mode.
LED
Meaning
indication
Yellow
No supply voltage
Green
Yellow
Undervoltage
Green
Yellow
Overvoltage
Green
Yellow
Output switched
Green
off; outside the
enable zone
(operating mode)
or inside the
enable zone
(adjustment mode)
Yellow
Output switched;
Green
inside the enable
zone (operating
mode)
Operating instructions
IN4000 Direct
Output state of the
outputs
OUT1
OUT2
(OSSD1)
(OSSD2)
0
0
0
0
0
0
0
0
1
1
8012183/WI13/2013-01-15
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido