Terminal Board
ALIM
+ / -
BATT
+ / -
+ DA DB -
RS485 - 3
E
+ DA DB -
RS485 - 2
N
DA DB -
RS485 - 1
G
L1 <---> L3
L 4
-
T
+ / -
VLINEE
[C] [NC] [NO]
A B
A' B'
OC
1 < ---> 8
FA
TA
+ / -
RESET
J3
PLUG - USB
J5
J6
J8
OC
9 < ---> 16
S3
S4
SW1
SW2
F1 - F5A 250V
F2 - F3.15A 250V Positive output protection of Open Collector outputs supplying
F3 - F3.15A 250V Positive output protection of serial supplying (RS485) number 3
F4 - F3.15A 250V Positive output protection of serial supplying (RS485) number 2
F6 - F3.15A 250V Positive output protection of detectors supplying (VLINES)
TERMINALS ON THE LEFT SIDE OF THE BOARD
Supplying input from 13,5 V
Uscita per il collegamento della batteria
TERMINALS ON THE BOTTOM SIDE OF THE BOARD
Serial n. 3 for connection of the serial peripherals; do not address two or more peripherals with the
same address even if connected on separate serials
Serial n. 2 for connection of the serial peripherals. Do not address two or more peripherals with the
same address even if connected on separate serials
Serial n. 1 for connection to the control panel
UNIVERSAL mode: input lines at double balancing
SERIAL mode: input lines at single or double balancing
The lines, if not used, must necessarily be BALANCED
The opening indication will be in series to an additional peripheral connected with address between 1
and 3. If these inputs are used, it is suggested to number the serial peripherals from 4 on.
UNIVERSAL mode: the input line dedicated to the indication of armed/disarmed system
SERIAL mode: line-managed as inputs L1 <---> L3
Negative reference input lines
Anti-tamper input, normally balanced with 4700 ohm resistance
Output for lines protected by fuse F6 3.15 A L 250V . It gives supplying to the detectors
Additional dry output (positive security) (C) common (NC) normally closed (NO) normally open
UNIVERSAL mode: it shows the TAMPER of one of the peripherals connected in RS485 and of
itself
SERIAL mode: it shows the alarm/tamper of the inputs according to the control panel programming
Input of main telephone line
Output telephone line for connection of the inside telephone lines
TERMINALS ON THE UPPER SIDE OF THE BOARD
UNIVERSAL mode: 50 mA transistorized outputs giving a negative according to the peripherals
status connected with address from 1 to 8
SERIAL mode: 50 mA transistorized outputs giving a negative. Configuration in various modes.
!!!ATTENTION!!! with jumper S4 closed, the O.C. outputs are disabled
(Fail) It gives a transistorized negative (50 mA) which misses when a problem and microprocessor
block occurs
UNIVERSAL mode: (tamper) It gives a 50 mA transistorized negative which misses when a satellite
or detector tampering occurs
SERIAL mode: (tamper) It gives a 50 mA transistorized negative which misses when a satellite
tampering occurs
Output protected by fuse F2 3.15A L 250 V. It gives supplying to the Open Collector outputs
It reset all alarms and phone calls on, maintaining the arming status unvaried
Output for direct connection to PC via USB
Connector for external accessories (optional)
Connector for external accessories (optional)
UNIVERSAL mode: connector for OC outputs extension board (optional mod. XOC8); 50 mA
transistorized outputs giving a negative according to the status of the peripherals connected with
address from 9 to 16
SERIAL mode: not used
!!!ATTENTION!!! with jumper S4 closed the O.C. outputs are disabled
Jumper for activation of the system with battery only, no mains
Jumper for activating of USB connection; CLOSED activates USB and deactivates O.C. and the
functions Acquisition and Detectors cancellation
Dip for satellite configuration
Dip for satellite address
Positive output protection of battery supplying
to 14,5 V
OTHER ELEMENTS
FUSIBILI
- 26 -