Connections for the
Millennium
Connections for the
equipment installed on
the bottom
Connections of water
inlet and drain
Use the hose-union fitting, silicon hoses and bayonet fittings of the supplied kit (Ref. 4 –
page 4) and carry out the connections as shown in the figure. Fasten by clamps the
hoses connected to hose-union fittings.
F
OR STERILIZER MODELS OTHER THAN
.
SUPPORT
N
O HYDRAULIC CONNECTION IS INTEGRATED ON
S
TERILIZER OR FOR THE
THEREFORE IT MUST BE MADE APART BY THE USER
Use the content of the supplied kit (Ref. 3 – page 4).
Connect the water drain sheathed hose to the nipple F through an hose-union (seal with
Teflon tape and fasten the hose by clamp).
Connect the hose (not supplied) coming from the water plant to the nipple G.
Central drain
(sink, etc.)
To water plant
Start-Stop cable
(from Milldrop)
Water fill
Water drain
NOTE
M
,
ILLENNIUM
CONTACT THE
NOTE
M
ILLRACK FOR AN ADDITIONAL
M
ILLWASHING INSTALLED ON THE BOTTOM
.
Teflon
Seal
C
USTOMER
;
13