808-012.book Seite 21 Freitag, 15. Dezember 2006 11:35 11
PerfectCharge IU812
Caution!
Batteries with a cell short circuit may not be charged. There is a
danger of explosions due to the explosive gases.
Nickel-cadmium batteries and non-rechargeable batteries may not
be charged with the IU0U automatic charger. The sleeves of these
batteries can burst in an explosive manner.
Note:
Only use cables with the prescribed cross sections to connect the
IU0U automatic charger:
– Cable lengths of up to 2 m: ≥ 1.5 mm²
– Cable lengths of up to 5 m: ≥ 2.5 mm²
Fit wire sleeves to the ends of cables which you wish to connect to the
IU0U automatic charger (Fig. 2 1, Page 3).
Use crimping tongs (Fig. 2 2, Page 3) and make sure the the wire
sleeves are fitted tightly (Fig. 2 1, Page 3).
Connect the cables (Fig. 3 1, Page 3) to the two terminals on the front
side as follows:
– Positive terminal (Fig. 3 2, Page 3): red cable
– Negative terminal (Fig. 3 3, Page 3): black cable
Connect the battery to the IU0U automatic charger:
– Positive terminal of the battery: red cable
– Negative terminal of the battery: black cable
Connect the 230 V mains power cable to a 230 V socket.
The IU0U automatic charger now charges the battery and supplies the
consumer with current if necessary.
All manuals and user guides at all-guides.com
Fitting the automatic charger and putting it into service
21