Descargar Imprimir esta página

Model Specifications - Liberty Pumps 250-Serie Manual De Instalación

Ocultar thumbs Ver también para 250-Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

MODEL SPECIFICATIONS

Model
HP
Volts
250*
1/3
115
251
1/3
115
253
1/3
115
257
1/3
115
250HV*
1/3
230
251HV
1/3
230
257HV
1/3
230
115
280*
1/2
281
1/2
115
283
1/2
115
115
287
1/2
280HV*
1/2
208-230
281HV
1/2
208-230
283HV
1/2
208-230
287HV
1/2
208-230
290*
3/4
115
291
3/4
115
293
3/4
115
297
3/4
115
290HV*
3/4
208-230
291HV
3/4
208-230
3/4
293HV
208-230
3/4
297HV
208-230
1/3
FL31M*
115
1/3
FL31A
115
1/3
FL32M*
208-230
FL32A
1/3
208-230
FL51M*
1/2
115
FL51A
1/2
115
FL52M*
1/2
208-230
FL52A
1/2
208-230
FL61M*
6/10
115
FL61A
6/10
115
FL62M*
6/10
208-230
FL62A
6/10
208-230
FL102M*
1
208-230
FL102A
1
208-230
FL103M*
1
208-230 3 PH
FL104M*
1
440-480 3 PH
FL105M*
1
575 3 PH
FL152M*
1-1/2
208-230
FL152A
1-1/2
208-230
FL153M*
1-1/2
208-230 3 PH
FL154M*
1-1/2
440-480 3 PH
FL155M*
1-1/2
575 3 PH
FL202M*
2
208-230
FL202A
2
208-230
FL203M*
2
208-230 3 PH
FL204M*
2
440-480 3 PH
FL205M*
2
575 3 PH
 Note: Manual models ("M" suffix) and 3 phase models, as designated above, require a separate approved pump control device or panel for automatic
operation. Operation of these models will be according to the control selected. Make sure the electrical specifications of the control selected properly
match the electrical specifications of the pump. 3 phase models require overload elements selected or adjusted in accordance with the control or panel
instructions.
Full Load Amps
Solids Handling
5.2
5.2
5.2
5.2
2.6
2.6
2.6
8.5
8.5
8.5
8.5
4.6
4.6
4.6
4.6
10.4
10.4
10.4
10.4
5.3
5.3
5.3
5.3
13
13
7
7
12
12
7
7
13
13
7
7
12
12
9
4.5
3.3
15
15
10.6
5.3
4.9
15
15
10.6
5.3
4.9
©Copyright 2012 Liberty Pumps Inc. All rights reserved
Automatic
Or Manual*
1/2"
Manual*
1/2"
Automatic
1/2"
Automatic
1/2"
Automatic
1/2"
Manual*
1/2"
Automatic
1/2"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Automatic
3/4"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Automatic
3/4"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Automatic
3/4"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Automatic
3/4"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Manual*
3/4"
Automatic
1/2"
Manual*
1/2"
Automatic
1/2"
Manual*
1/2"
Automatic
1/2"
Manual*
1/2"
Automatic
1/2"
Manual*
1/2"
Automatic
3/4"
Manual*
3/4"
Automatic
3/4"
Manual*
3/4"
Manual*
3/4"
Manual*
3/4"
Manual*
3/4"
Automatic
3/4"
Manual*
3/4"
Manual*
3/4"
Manual*
3/4"
Manual*
3/4"
Automatic
3/4"
Manual*
3/4"
Manual*
3/4"
Manual*
Factory Switch Setting
Shut-off Head
Turn-on
22 ft.
*
22 ft.
11"
22 ft.
11"
22 ft.
7"
22 ft.
*
22 ft.
11"
22 ft.
7"
37 ft.
*
37 ft.
13"
37 ft.
13"
37 ft.
9-1/2"
37 ft.
*
37 ft.
13"
37 ft.
13"
37 ft.
9-1/2"
48 ft.
*
48 ft.
13"
48 ft.
13"
48 ft.
9-1/2"
48 ft.
*
48 ft.
13"
48 ft.
13"
48 ft.
9-1/2"
19 ft.
*
19 ft.
12"
19 ft.
*
19 ft.
12"
48 ft.
*
48 ft.
12"
48 ft.
*
48 ft.
12"
63 ft.
*
63 ft.
12"
63 ft.
*
63 ft.
12"
90 ft.
*
90 ft.
15"
90 ft.
*
90 ft.
*
90 ft.
*
110 ft.
*
110 ft.
15"
110 ft.
*
110 ft.
*
110 ft.
*
130 ft.
*
130 ft.
15"
130 ft.
*
130 ft.
*
130 ft.
*
Turn-off
4-1/2"
4-1/2"
3-1/2"
4-1/2"
3-1/2"
7"
7"
4"
7"
7"
4"
7"
7"
4"
7"
7"
4"
5"
5"
5"
5"
5"
5"
*
8"
*
*
*
*
8"
*
*
*
*
8"
*
*
*
3

Publicidad