Fault finding

Fault
The appliance is
"dead"!
Water collects in
the bottom of the
cabinet.
Vibration or
bothersome noise.
Compressor runs
continuously.
E1 is shown on the
display.
E is shown on the
display.
ULO is shown on
the display.
UHI is shown on the
display.
Possible cause
The appliance is switched off.
Power failure; the fuse is blown;
the appliance is not plugged in
correctly.
The defrost water pipe is
blocked.
The appliance is not level.
The appliance is resting against
other kitchen elements.
Containers or bottles inside the
cabinet are rattling against one
another.
High room temperature.
The upper sensor is disconnect-
ed or short-circuited.
The lower sensor is disconnected
or short-circuited.
The mains voltage is lower than
184 V.
The mains voltage is higher than
255 V.
Remedy
Press the on/off switch.
Check that power is connected.
Reset the fuse.
Clean the defrost water channel
and the drain hole on the rear
wall of the cabinet.
Level the appliance using a spirit
level.
Move the appliance away from
the kitchen elements or appli-
ances it is in contact with.
Move containers and/or bottles
apart.
Ensure adequate ventilation.
Call for service. The temperature
within the entire cabinet is main-
tained at the higher of the two
setpoints until the fault has been
corrected.
Call for service. The temperature
within the entire cabinet is main-
tained at the higher of the two
setpoints until the fault has been
corrected.