EMERGENCIES:
Jf a gas leak cannot
be stopped, or a fire occurs due to gas Jeakage_ call the fire department.
Gas leaking from
cracked/cut/burned
hose.
" Damaged
hose.
*Turn off gas at LP cylinder or at source on natural gas systems. If the hose
s cracked or cut but not burned, simply replace valve / hose / regulator.
Jfthe hose is burned,the cause could be other than a faulty valve/hose/
regulator. Discontinueuse of grill until a plumber or gas technic an has
nvestgated and corrected the problem_
GasbakingfromLP
" Mechanical f ailuredueto rusting or
• Replace LP cylinder.
cylinder,
mishandling.
GasleakingfromLP
• Failure of cylindervalvefrommishandling
• Turnoff LP cylindervalve.Return LP cylinderto gassupplier.
cylindervalve,
or mechanical failure.
Gasbaking between LP
" improperinstallation, connection not
• Turnoff LP cylindervalve.Remove regulatorfromcylinderandv suaJJy
cylinderandregulator
tight,failureof rubberseal,
inspectrubbersealfor damage. S eeLP CylinderLeakTest a ndConnecting
connection.
Regulator
to the LP
Cylinder.
Fire coming through
" Fire in burner t ubesectionof burner
*Turnoff controlknobsandLP cylindervalve.Leave lid opento allowflames
contrd panel,
dueto blockage,
to diedown.Afterfire isoutandgrill iscold, remove burnerandinspect
forspidernests or rust. S eeSpider A lertandCleaning the Burner A ssembly
sections of thisUse& CareGuide.
excessive flamesabove
to die down.After
coding,
dean food
particles
andexcess greasefrom
cookingsurface,
inside fireboxarea,greasetray,andothersurfaces.
Troubleshooting
Burner(s) will not light
using igniter. (See
Electronic ignition
Troubleshooting also)
• See instructions on control panel and in Use and Care section.
Make sure valves are positioned inside of burner tubes.
" Trying to light wrong burner.
• Burner not engaged
with control
valve.
• Obstruction in burner.
Wires are shorting (sparking)
between igniter and electrode.
Ensureburner tubes are not obstructed with spider webs or
other matter. See cleaning section of Useand Care.
No gas flow.
• Make sure LPcylinder is not empty. If LPcylinder is not empty,
refer to "Sudden drop in gas flow."
• Vapor lock at coupling nut to LP
• Turn off knobs and disconnect coupling nut from LPcylinder.
cylinder.
Reconnect and retry.
• Coupling nut and LPcylinder valve not
• Turn the coupling nut approximately one-half to three-quarters
fully connected,
additional turn until solid stop. Tighten by hand only - do not use
tools,
• Electrode cracked or broken; "sparks
• Replace electrode(s).
at crack.
• Electrode tip not n proper position.
Main Burners:
° Tip of electrode should be pointing toward gas port opening
on burner. The distance should be 1/8" to 1/4'. Adjust if
necessary.
cooking residue,
swab,
• Wires are loose or disconnected.
• Reconnect wires or replace electrode/wire assembly.
• Replace igniter wire/electrode assembly.
• Dead battery.
• Replace with a new AAA-size alkaline battery.
REV 2