Dimplex DFR2551L El Manual Del Propietario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fireplace Installation
insert directly on carpet or
similar surfaces which may
restrict air circulation.
CAUTION: If installing the fire-
place in a carpeted area, place a
one-piece, solid, flat surface under
the fireplace. Ensure that all of the
feet rest securely on this surface.
4. The firebox is to be installed
from the front of the mantel and
inserted so that the flanges are
flush against the front surface of
the mantel.
Figure 5
Wiring Diagram
8
Holes for plastic
feet
ELEMENT
BLOWER
MOTOR
M
+T°
RELAY BOARD
SWITCHBOARD
DISPLAY-CONTROL BOARD
Bathroom Installation
This firebox must be protected by
a GFI receptacle or circuit. If a re-
ceptacle is used it must be readily
accessible.
To prevent electrical shock this unit
is an electrical appliance that is not
watertight and must be installed
as to prevent water from entering
the unit. This unit must be installed
away from showers, tubs, etc.
Never locate fireplace where it may
fall into a bathtub or other water
containers.
CUTOUT
M
FLICKER
MOTOR
MEDIA BED RGB LED STRIP
LOGSET ASSEMBLY
MEDIA BED LED ASSEMBLY
LOGSET LED ASSEMBLY
LED LIGHT ASSEMBLY
THERMISTOR
L
N
120V / 12V
~
AC/DC
ADAPTER
AC / DC
www.dimplex.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dfr2551g69089223596908922459

Tabla de contenido