EmberGlow VFF15NLA Manual De Instalación Y Funcionamiento Del Propietario página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING: Test all gas piping
and connections for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply
a noncorrosive leak detection
fluid to all joints. If bubbles form,
there is a leak. Correct all leaks
at once.
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect heater with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping sys-
tem. Pressures in excess of 1/2 PSIG will
damage heater regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane supply tank valve for
propane gas or opening main gas valve
located on or near gas meter for natural
gas or using compressed air.
4. Check all joints of gas supply piping sys-
tem. Apply noncorrosive leak detection
fluid to all joints. If bubbles form, there
may be a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Equipment
Shutoff Valve
Figure 15 - Equipment Shutoff Valve
16
INSTALLATION
CHECKING GAS CONNECTIONS
Open
Closed
www.sureheat.com
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-
ure 15).
2. Pressurize supply piping system by either
opening propane supply tank valve for
propane gas or opening main gas valve
located on or near gas meter for natural
gas or using compressed air.
3. Check all joints from gas meter to equip-
ment shutoff valve for natural gas or
propane supply to equipment shutoff valve
for propane (see Figure 16 or 17). Apply
a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Propane
Supply Tank
External Regulator with
Vent Pointing Down
Figure 16 - Checking Gas Joints for
Propane Gas
Gas Meter
Equipment Shutoff Valve
Figure 17 - Checking Gas Joints for
Natural Gas
Equipment
Shutoff Valve
Control Valve
Location
Control Valve
Location
200176-01B

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido