The pump operates exactly the same as a pump with a "start-stop" system and flow and pressure
control. When the pressure drops below the set value the pump starts, when the tap is turned off the
pump stops, if there is a lack of water the pump stops and a warning is signalled on the pump's control
panel. After a preset time the pump automatically starts again and if all operations are within the set
parameters the pump carries on operating normally.
The system also includes a special anti-stench and anti-draining trap.
Figure 01
1.
pump control panel
2.
pressurised water outlet
3.
recovery tank suction
4.
3-way valve
5.
mains water collection tank
6.
trap overflow
7.
pump
8.
mains water inlet
9.
pump filler plug