6. Pump control panel
Control panel description.
7. Maintenance
The system does not require periodic maintenance.
WARNING
Before touching the unit, disconnect the plug from the mains socket, make sure that the on-off valves
are closed and that no one can reconnect the power supply or open the valves during inspection.
Float valve, make sure that the valve closes hermetically and that the float is able to move freely.
Pump, check that it delivers the correct pressure and that it does not emit mechanical noises or
whistles.
Water leaks, check that the connections do not leak.
Sensors, make sure that the float switch is working correctly when cleaning the rain water
collection tank.
The above mentioned operations can be performed as precautionary measures every 6-12 months.
8. Trouble shooting
fault
Pump alarm LED.
Water leak from the trap
discharge pipe.
cause
Lack of water.
Motor or impeller blocked. Make sure that the impeller is free of dirt.
Motor overheating.
Hydraulic regulator
blocked by limescale.
The hydraulic regulator
float touches the side of
the tank.
Mains pressure too high.
30
1.
pump ON green LED
2.
pump in alarm red LED
solution
When the water returns, disconnect and
then reconnect the power supply plug, the
reset occurs automatically at preset time
intervals.
Make sure the mains flow rate is over 10
l/min.
Make sure that there are no obstacles
blocking the air intake and outlet.
Fit a filter against limescale.
Slacken the hydraulic regulator locking ring,
and move the float so that it no longer
touches the side of the tank, then tighten
the locking ring again.
Install a pressure regulator on the inlet to
the mains tank.