Descargar Imprimir esta página

Indoor Unit - Taurus TAS-2250 Manual De Instalación

Aire acondicionado con bomba de calor
Ocultar thumbs Ver también para TAS-2250:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
open the high/low pressure valves in
an anticlockwise direction.
Test procedure
-Before carrying out the test, check
that all the wires and channelling are
safe and correctly connected, the valves
are completely open and the apparatus
is situated on a solid base.
-If the power supply is switched on, a
'beep' will be heard from the indoor
unit.
-Switch the apparatus on using the
remote control handset.
-If the temperature of the room is
between 0ºC and 20ºC, select the
heating mode and establish a
temperature of 25ºC to test that the
heating mode works.
-If the temperature of the room is
between 20ºC and 45ºC, select the
refrigeration mode and establish a
temperature of 16ºC to test that the
refrigeration mode works.
Warning
Consult the following questions related
to the contents of the user instruction
manual.

Indoor unit

Does it make a strange noise?
Do the indicator lights activate without
any problem?
Does the condensation flow without
any problem?
Outdoor unit
Does it make any strange noise or
vibration while functioning?
Does the noise, the air outlet or the
drainage affect the neighbours?
Are there any gas leaks?
Remote control handset
Do the buttons work correctly?
Does the indoor unit 'beep' when it
receives the signal from the remote
control handset?
User guidelines
-Once the installation has been carried
out, explain the following procedures
to the user:
-Use the instruction manual to explain
the normal use of the apparatus, the
utility of each function and any other
information which they should know.
-How to remove the air filters and use
the sweeping mode.
-How to remove and replace the
batteries of the remote control handset.
-The user must read the user instruction
manual carefully before using the
apparatus.

Publicidad

loading

Este manual también es adecuado para:

Tas-3000Tas-4500Tas-6000