Troubleshooting - Slingshot Field Hub Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29

Troubleshooting

The following information addresses some potential issues you may
encounter with the Field Hub™:
Issue
Field Hub does
not power up
(power indicator
not lit)
DGPS receiver
not receiving
RTK corrections
No signal
indicator status
or no data
transferring
Possible
Cause
• Power cable not
connected
• Power cable is
damaged or
broken
• Fuse(s) broken
• No RTK unlock
key or code
• Slingshot™ RTK
subscription not
activated
• CORS network
unable to send
corrections
• Cellular
antennas not
connected
• Antenna cable(s)
damaged or
broken
• Wrong antenna
band (i.e. radio)
connected to
Field Hub
• No cellular signal
at current
location
Solution
• Verify 4-pin power cable is connected to Field
Hub.
• Check cable for crimping, fraying or breakage.
• Check fuses. Replace as needed.
• Check with your DGPS receiver dealer or
manufacturer and verify the receiver has been
unlocked or is compatible with RTK corrections.
• Contact your local Slingshot dealer for
availability or obtain a subscription.
• Some CORS networks will not forward
correction messages until a GPS location is
received. Ensure the GPS patch antenna is
connected and the GPS LED is on.
• Verify the cellular antennas are connected to
the 'Antenna' and 'Diversity' ports on the back
of the Field Hub.
• Check antenna cables for crimping, fraying or
breakage.
• Remove the antenna currently connected to the
Field Hub and replace with the supplied
antenna or a suitable replacement cellular
antenna.
• Check with your service provider for area
coverage. Coverage may vary depending upon
usage and peak hours.