Digital laser measure
Protection rating
Measuring rail
Article number
Dimensions
Battery
Rated voltage
Capacity
Number of battery cells
Individual measurements per battery charge approx.
Charger
Article number
Charging time
Battery charging voltage
Charge current
Protection class
A) For measurements from the front edge of the measuring tool, 100% reflectivity of the target (e.g. a white wall), weak backlighting and 25 °C
operating temperature. In addition, a deviation influence of ± 0.05 mm/m needs to be taken into account.
B) For measurements from the rear edge of the measuring tool, 10–100 % reflectivity of the target, strong backlighting and 25 °C operating
temperature. In addition, a deviation influence of ± 0.29 mm/m needs to be taken into account.
C) For measurements that use the back of the device as a reference, the max. measuring range amounts to ± 60°
D) After calibration in accordance with figure H. Additional pitch error of ± 0.01°/degree up to 45°.
E) The width of the laser line depends on the surface characteristics and on the ambient conditions.
F) In continuous measurement mode, the max. operating temperature is +40 °C.
G) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
H) At 25 °C
I)
For a new and charged battery without display illumination and sound.
The serial number (18) on the type plate is used to clearly identify your measuring tool.
Please observe the article number on the type plate of your battery charger. The trade names of individual battery chargers may vary.
Initial start-up
Charging the battery
Use only the chargers listed in the technical data. Only
u
these chargers are matched to the lithium-ion battery of
your measuring tool.
The use of chargers from other manufacturers can
u
lead to defects on the measuring tool; a higher voltage
(e.g. 12 V) from a vehicle charger is not suitable for
charging this measuring tool. The warranty is
rendered void if these instructions are not followed.
Pay attention to the mains voltage. The voltage of the
u
power source must match the voltage specified on the
rating plate of the charger.
Note: The battery is supplied partially charged. To ensure
full capacity of the battery, completely charge the battery
before the first use.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
Bosch Power Tools
GLM 80
IP 54 (dust and splash-proof) IP 54 (dust and splash-proof)
–
–
Li-ion
3.7 V
1.25 Ah
1
I)
25000
2 609 120 7..
1 600 A01 3..
approx. 3 h
5.0 V
1000 mA
/ II
If the lower segment of the battery charge indicator (g)
flashes, only a few more measurements can be made.
Charge the battery.
If the frame around the segments of the battery charge indic-
ator (g) flashes, no more measurements are possible. The
measuring tool can only be used for a short time (e.g. to
check entries in the measured value list). Charge the bat-
tery.
Connect the measuring tool to the charger (23) using the mi-
cro USB cable (22) provided. Plug the charger (23) into the
socket. The charging process will begin.
The battery charge indicator (g) indicates the charging pro-
gress. The segments flash successively during charging.
When all segments of the battery charge indicator (g) are
displayed, the battery is fully charged.
If you are not planning to use the power tool again soon, dis-
connect the charger from the mains.
The battery can also be charged at a USB port. To do so, con-
nect the measuring tool to a USB port using the micro USB
cable. In USB mode (charging mode, data transfer), the
charging time can be noticeably longer.
English | 21
GLM 80+R 60
3 601 K79 000
58 x 610 x 30 mm
Li-ion
3.7 V
1.25 Ah
1
I)
25000
2 609 120 7..
1 600 A01 3..
approx. 3 h
5.0 V
1000 mA
/ II
1 609 92A 55A | (05.08.2019)