007 - Flame problem
008 - Black Out
009 - Security entry
012 - Smoke temperature error
013 - Smoke extractor alarm
- Lack of pellets.
- Température de la fumée
très basse.
- Lack of electricity more
than 5 s.
The pressure switch unactivated:
- Door open.
- The pipe is blocked, low air
call, the installation is not in
the established standards.
- Pressure switch pipe
blocked.
- Smoke extractor malfunction.
- Pressure switch broken.
- 120º temperature control
active or damaged.
Intervention of the 120º
temperature control
- Anomalous intervention due
to a burr on the base of the
temperature control.
- Pellets loader overheat.
- Damaged circuit board.
Temperature control
manual restart
- Air fan damaged moving.
- Incorrect operation parameters.
- Triac (extraction engine)
malfunction on the circuit board.
- Damaged temperature controller.
CABLE
- Wrong connection of 2 plugs
on the circuit board.
- Plugs not connected.
- Damaged plugs.
- If during ignition, smoke
sensor does not read the
temperature variation during
5 minutes it means that the
circuit board is damaged.
- Wrong circuit board connection.
Apears during ignition.
- Wrong plug connectio.
- Engine or encoder damaged.
(deactivate technical menu).
Contact the technical
assistance center.
To reload press key 1
Contact the technical
assistance center.
Contact the technical
assistance center.
Contact the technical
assistance center.
Contact the technical
assistance center.
Contact the technical
assistance center.
Contact the technical
assistance center.
92
------------------------------
Display will turn on when
the wood stove will be powered.
Clean the wood stove.
5.0 Cleaning and mantain
Annex:
Quick security and ignition
guide.
------------------------------
------------------------------
------------------------------
Make sure that during ignition
you have some pellets.
------------------------------