Converting Appliances For Use With Ng Gas; Pressure Regulator Conversion - FULGOR F5PGK305S1 Instrucciones De Installación

Placa de cocción profesional de gas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
1
2
After injectors replacement adjust the burner flame (see Low
Flame Adjustment paragraph).
Check the appearance of each burner's flame at HILO
settings, if the flame appear too large or too small make
sure that all steps were completed correctly.
Convert the pressure regulator on LP position following the
illustration.

Converting Appliances for Use with NG Gas

If this appliance should be converted for use with gas NG
(natural gas), each of the following modifications must be
performed.
1. Replace all injectors following the step described on
page 15, observe the number stamped on the side,
this number codes the orifice diameter and its correct
burner location (following the illustration of injectors
position).
2. Convert the pressure regulator on LP position (following
the illustration of pressure regulator conversion).
3. Adjust the burner flame (see Low Flame Adjustment
paragraph).
Check the appearance of each burner's flame at HILO
settings, if the flame appears too large or too small make
sure that all steps were completed correctly.
16

Pressure regulator conversion

The appliances is designed for use with NG gas or LP gas.
The gas pressure regulator is supplied. It must be installed
in the gas way ahead of manifold entrance. It is pre-set for
use with the gas supplied with the appliances. For use with
different gas must be converted.
For the pressure regulator conversion following the below
instructions:
• Disconnect all electrical power, at the main circuit breaker
or fuse box.
• Shut off the gas supply to the cooktop by closing the
A
manual shut-off valve.
• Adjust the pressure regulator, by following the instruction
(see figure)
B
1. Unscrew the regulator cap
2. Unscrew the plastic conversion plug from the cap turn
over and screw back (wide section away from cap for LP
and against cap for NG) see figures below.
3. Replace the cap regulator.
PRESSURE REGULATOR CONVERSION
NG POSITION
PLUG
NG
Before replacing the regulator cap, check if the position
of plug is suitable for the gas
CAP
GASKET
LP/PROPANE POSITION
PRESSURE REGULATOR
LP

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

F6pgk305s1F5pgk365s1F6pgk365s1

Tabla de contenido