Generic
This section may be used to set the audio levels of the loudspeaker and microphone fitted to the GSM transmitter.
Speaker volume: the volume of the loudspeaker may be adjusted by shifting the cursor.
Microphone volume: the volume of the microphone may be adjusted by shifting the cursor.
Tones...: select the name of Communicator's country of installation: the selected country will establish a series of
parameters for the proper working of the simulated telephone call.
LE failure timeout : the time in seconds (between 10 and 3600 seconds) may be entered in this box; once this time
has elapsed the Communicator will indicate a Breakdown on the LE terminals.
, , , , , The time may increase up to 60 seconds if some telephone devices are connected to the terminals LI.
LE restore timeout: the time in seconds (between 10 and 3600 seconds) may be entered in this box; in this period the
connection of the LE terminals must be restored, otherwise the Communicator will indicate a Breakdown on the LE
terminals.
Outputs
This section may be used to set the operating modes of the outputs.
Output 3 ON Time: the ON time in seconds may be entered in this field (between 0 and 86400 seconds).
Output 1, Output 2, Output 3: Check the box for output operation normally closed or normally open.
Primary Path: select the primary GSM or PSTN line using this field.
GPRS
This page outlines the GPRS configuration options.
, , , , , Bearing in mind the delays which may occur in transmission via GPRS, which are caused by the activities
of the network manager, we recommend you program as many call attempts to the burglar alarm control
panel as possible, and that you also provide a backup telephone number which transmits alarms via GSM
as well as via GPRS.
Access Point Name 1 and Acces Point Name 2
Enter the Access Point Name of the GPRS service provider being used. Enter the name of the IP address service provider
in this box. Access Point Name 2 is considered a backup parameter.
Receiver 1, Local Port 1 and Remote Port 1 IP address
Enter the primary receiver IP addresses and port numbers. Use the same IP address and Port that is found in the "Listening
Port " section of the WinBCS, while for Sur-Gard SYSTEM III and SYSTEM II enter the IP address and the port listed in the
Alarm Port section.
Receiver 2, Local Port 2 and Remote Port 2 IP address
This check box is used to enter the second IP address for the receiver and the port number, with the difference that these
parameters are considered as a backup receiver. The Communicator only recognises this box in the event that the
parameters relating to the Receiver 1, Local Port 1 and Remote Port 1 have not been entered. Furthermore, the Enable
Supervision and Supervision time may not be activated.
APN1 Username and Password, APN2 Username and Password
Some providers may require a user name and password to validate communication. If needed, enter this information here.
APN2 Username and Password are considered to be backup data.