Diagnostics Led - tau K100M Guía Para La Instalación

Panel de mandos para motorreductor t-one5e
Ocultar thumbs Ver también para K100M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIAGNOSTICS LED

DL1 (RADIO CONTROLS) / RED
DL2 (OPEN/CLOSE) / RED
DL3 (PHOTO) / GREEN
DL4 (CLOSE LIMIT SWITCH) / GREEN
DL5 (OPEN LIMIT SWITCH) / GREEN
DL6 (STOP) / GREEN
TERMINAL BOARD CONNECTIONS
Terminals
Function
1 - 2
POWER SUPPLY POWER input 230/115 V AC 50-60 Hz.
3 - 4
FLASHING LIGHT FLASHING LIGHT Output FLASHING 230/115 VAC 50 W max.
LED
5 - 6
FLASHING LIGHT
7 - 10
OPEN/CLOSE
8 - 10
STOP
9 - 10
PHOTOCELLS
24V AC
11 - 12
PHOTOCELLS
13 - 14
AERIAL
J4
APP
M2
LIMIT SWITCH
FS1 - FS2
CAPACITOR
M3
MOTOR
SM
MEMORY CARD
LOGIC ADJUSTMENTS
TRIMMER
Motor torque adjustment. Turning the trimmer clockwise (+) the torque will be increased; Turning the trimmer coun-
terclockwise (-) the torque will be decreased.
FR.
Note: The trimmer is set to provide sufficient thrust to work the gate within the limits established by
current standards (EN 12453).
Obstacle detection
counterclockwise (-) the sensitivity will be decreased.
SENS.
Note: Before setting the obstacle detection, let the gate operator perform a complete opening and clos-
ing cycle.
Automatic closing time adjustment. Turning the trimmer clockwise (+) time will be increased; Turning the trimmer
T.C.A.
counterclockwise (-) the time will be decreased.
Note: The time values can be set between 1 and 120 seconds.
Dip switch
On automatic closing enabled.
AUTOMATIC
1
CLOSING
Off automatic closing disabled.
On
2
2 / 4 STROKE
Off
On
3
SOFT-STOP
Off
On
OPENING
4
DIRECTION
Off
On While opening and during the T.C.A., the gate ignores the closing commands (NO REVERSE);
5
NO REVERS
Off The gate behaves as per the setting of dip-switch 2;
On breaking enabled;
6
BREAKING
Off breaking disabled;
Note: the breaking system activates whenever the motor must stop and reduces the inertia accumulated by the gear motor
during movement.
SOFT-STOP SETTING
ERROR message / PROGRAMMING of transmitters
OPEN / CLOSE pushbutton activated
PHOTOCELL activated
CLOSING LIMIT SWITCH activated
OPENING LIMIT SWITCH activated
STOP pushbutton activated
Description
FLASHING LIGHT Output FLASHING 12 VDC. Intermittent output during the operation, the flashing frequency is
doubled during closing;
OPEN/CLOSE input (Normally Open contact);
STOP input (Normally Closed contact);
PHOTOCELLS OR SAFETY DEVICES input; active during closure (Normally Closed contact); the gate will stop
during closing and totally reopen it, (10= Common).
contacts IN SERIES.
24 V AC 10 W output to Photocells, Receivers etc.; connect a up to 3 pair of photocells. 11= 0 V AC, 12= 24 V AC;
433,92 MHz built-in RX aerial input; 13= EARTH, 14= SIGNAL;
quick plug-in for device connection for APP operation (mod. T-WIFI / T- CONNECT)
Quick coupling for LIMIT SWITCH connection (Normally Closed contacts).
ORANGE= Closing Limit Switch (CLS), RED= Opening LimitSwitch (OLS), GREY= Common (COM);
CAPACITOR Terminals for motor start-up;
Quick coupling for 230 V AC single-phase MOTOR connection. BLUE= common (M-COM);
BROWN= closing (M-CL); BLACK= opening (M-OP).
quick plug-in for MEMORY CARD connection for transmitters codes.
setting. Turning the trimmer clockwise (+) the sensitivity will be increased; Turning the trimmer
(with Automatic closing enabled) Two-Stroke operation mode OPEN-CLOSE, OPEN-CLOSE,
(with Automatic closing enabled) Four-Stroke operation mode OPEN-STOP-CLOSE-STOP, OPEN-
STOP-CLOSE-STOP,
etc.
Turning DIP3 ON, the setting of the travel with slowdown is activated (see following paragraph). At
the end of the procedure, leave the dip ON if you want to keep the values obtained. If you turn it
OFF and then back ON, the SETUP procedure must be repeated.
The working time is determined by the limit switches, no slowdown. Non-adjustable maximum working
time set at 96 seconds.
Left-hand leaf opening mode;
Right-hand leaf opening mode;
EARTH,
1= NEUTRAL, 2= PHASE;
If there is more than one safety device, connect all the NC
etc.

Publicidad

Tabla de contenido
loading

Tabla de contenido