MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
"PEDESTRIAN ENTRY" FUNCTION
BUILT-IN FLASHING LIGHT CIRCUIT
WEEKLY TIMER INPUT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
OPERATING TIME FIXED AT 120 sec.
AUTOMATIC DETECTION OF THE FEEDING FREQUENCY (50 or 60 Hz)
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input). The
go off only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The light
up only when the controls to which they are associated are operated.
Power input to board
Nominal power
Fast acting fuse for protection of input power supply 230 Vac (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
Fast acting fuse for protection of auxiliary circuits 24 V dc (F2 - 5x20)
Working temperature
Box protected to
DL1
PHOTOCELL green LED signal
DL2
SENSITIVE EDGE green LED signal
DL3
CLOSE LIMIT SWITCH green LED signal
DL4
OPEN LIMIT SWITCH green LED signal
DL5
STOP button green LED signal
DL6
PEDESTRIAN button red LED signal
DL7
OPEN/CLOSE button red LED signal
DL8
RADIO CONTROLS programming red led
TAU
Srl
CONTROL PANEL FOR ONE 230 Vac MOTOR
K570M
English
TESTING
230 Vac - 50 Hz
400 W
F 3,15 A
230 Vac
24 Vac
F 500 mA
-20°C ÷ +70°C
IP 44
DIAGNOSTICS LED
11