tau D703 Guía Para La Instalación página 13

Panel de mandos para motor monofasico-trifasico 230/400 vca
Ocultar thumbs Ver también para D703:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9 - 11
PEDESTRIAN
12 - 13
OPEN/CLOSE
12 - 14
OPEN
12 - 15
CLOSE
FIXED SAFETY
16 - 17
EDGE
16 - 18
PHOTOCELL
19 - 20
CLS (FCC)
19 - 21
OLS (FCA)
22 - 23 - 24 ENCODER
GATE OPEN
25 - 26
WARNING LIGHT
27 - 28
PHOTOCELL TX
29 - 30
PHOTOCELL
31 - 32
AERIAL
33 - 34
2
RADIO CH
nd
C
RECEIVER
PEDESTRIAN button input (normally open contact); partially
opens the automatic system (by about 1 m) to allow pedestri-
ans to pass by (common=9);
OPEN/CLOSE button input (contact normally open); for oper-
ating information see dip switch 2 and 8 functions;
OPEN button input (contact normally open); for operating in-
formation see dip switch 3 functions (common=12);
CLOSE button input (contact normally open); for operating
information see dip switch 3 functions (common=12);
FIXED SAFETY EDGE input (normally closed contact); only
works during the opening phase by temporarily stopping the
gate and then closing it again by approx. 20 cm. A manual
command is required to continue operation (common=16);
PHOTOCELL or SAFETY DEVICES input (normally closed
contact); if these trigger during the closing phase, the gate
stops and then completely reopens. During the opening
phase it temporarily stops the gate until the detected obsta-
cle has been removed (if programmed, dip switch 9 to ON),
(common=16);
Note: the photocell transmitter must always be connect-
ed (terminals 27 and 28) as it is checked by the safety
system; the control unit will not work if it is disconnect-
ed. To disable the safety system move dip switch 6 to
OFF.
CLOSE LIMIT SWITCH input (normally closed contact),
(common=19);
OPEN LIMIT SWITCH input (normally closed contact),
(common=19);
Note: the thermal protection (for MASTER20T and BIG-
18QI only) must be wired in series to the common of the
limit switch (terminal 19).
ENCODER power input
22 BLEU = common, 23 BROWN = +5V, 24 WHITE = signal;
ENCODER operation is governed by dip switch 5 (only for
motors with ENCODER);
GATE OPEN LED output; 24V AC, max. 3 W; the LED lights
up at the same frequency as the flashing light throughout the
opening and closing manoeuvres; it then stays on when the
OPEN LIMIT SWITCH (FCA) is reached and switches off
when the CLOSED LIMIT SWITCH (FCC) is reached;
24V AC power output (only for the photocell transmitter)
max. no. 1 photocell transmitter;
24V AC auxiliary power output (power input to photocells or
other devices);
AERIAL input (earth=31, signal=32) (only for RX 40.665MHz);
2
RADIO CHANNEL output;
nd
Warning: to connect other devices to the 2nd Radio
Channel (area lighting, pumps, etc.), use an additional
auxiliary relay (with receiver connected).
radio board connector.
D703
13

Publicidad

Tabla de contenido
loading

Tabla de contenido