1) Product description
The A100F control unit enables the control of overhead garage
doors and sliding gates equipped with single-phase alternate-cur-
rent gearmotors. It features a system for force adjustment and a
"constant resistance STOP" input (e.g. for sensitive edges).
The control unit features a number of functions that can be selected
using dip-switches (mini selector switches); some adjustments can
be made using trimmers, while a jumper enables the selection of the
I
L
M
N
!
If you need to replace a fuse, be careful to use one of the same type and having identical characteristics:
Dimensions (5x20), rated current (e.g. 5A), blowout characteristics (T=delayed, F=quick), maximum voltage and break-
ing capacity.
2) Installation
!
Automatic gate and door systems may only be installed
by qualified fitters in the full respect of the law.
2.1) Mounting the A100F control unit
• Mount the control unit on a non-movable, flat vertical surface suit-
ably protected from impacts. Make sure that the bottom is at least
40cm off the ground.
• Insert the cable or tube leads through the bottom of the container
only (see figure 1a).
1a
A
B
C
G
H
F
S
TL
Q
R
O
P
type of automation: "Sliding / Overhead".
A number of LEDs located near the inputs signal their status, while
an additional LED located below the dip-switch (OK LED) signals the
correct operation of the internal logic.
A
B
C
D
D
E
F
G
H
I
E
L
M
N
O
P
Z
Q
R
S
T
U
V
T
V
Z
U
Comply with the warnings shown in the "Warnings for fit-
ters" file.
• The container is provided with a cover designed to protect the
electronic board from accidental contacts (see figure 1a).
The electronic board can be interfered with only in the event of real
need; in this case, proceed as shown in figure 1b.
1b
Transformer
"Common" relay
"Brake" relay
Microprocessor
SMX Radio connector
Low voltage fuse
"Open/Close" relay
"Pickup" relay
"Courtesy light" relay
Line fuse
Force selector switch (F)
Power supply terminal board
Flashing / C.tsy light / motor power
supply output terminal board
Input / output control terminal board
Working Time adjustment trimmer (TL)
Led OK
Function selection Dip-Switch
Pause Time adjustment trimmer (TP)
STOP input terminal board with constant
resistance 8.2KΩ (sensitive edge)
Selection jumper: overhead / sliding
Aerial terminal board
GB
3