Service & Maintenance - Atlantic TA400 Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

• Do not lift, lower or handle the pump by pulling on the electrical cord. Make sure the electrical
cable does not become excessively bent or twisted and does not rub against a structure in a
way that might damage it.
• The air pump should not be used if the electrical supply cable is damaged in any way. If a cable
with damaged insulation is submerged in water, there is danger of water seeping into the
pump motor and causing a short. Altering the electrical cable in any way will void the warranty.
Installation
Pump Placement
The following factors must be considered when choosing a location for the air pump.
• Typhoon Air Pumps feature weather-proof housings for outdoor use. However, installation
in a dry, well-ventilated area will further prolong the service life of the air pump.
• Typhoon Air Pumps must be placed on a flat, stable surface above the water level of the pond.
• Proper ventilation is critical for heat dissipation and operation. Never cover the air pump
unless adequate airflow to the pump is provided.
• Tubing must always be run on a downward slope away from the air pump to avoid
condensation damage.
Air Pump Connections
TAKIT0400 and TAKIT0800 Aeration Kits are supplied with ¼" I.D all-weather flexible tubing for
maximum airflow. Using large diameter tubing and avoiding sharp bends will improve perfor-
mance and efficiency of these air pumps. Never decrease the size of the tubing. In cooler weather,
the air produced by the TA400 and TA800 is often warmer than the ambient outside temperature.
These conditions will create condensation inside the flexible tubing. To prevent any water from
flowing backwards into the air pump when
powered off, it is recommended to elevate
the pump a minimum of 12" above the
surrounding grade. The tubing must
immediately run at a downward slope as it
exits the compressor. Gravity will carry the
moisture away from the air pump. In this
installation it is not necessary install
the check valve(s) supplied with this kit.
If the air pump is not elevated, the supplied check valve(s) must be installed. Cut a short 6"
piece of tubing from the supplied roll. Insert the unmarked side of the check valve into one
end of the 6" piece of tubing
and connect the other end to the
air pump. The remaining tubing
can then be connected to the other
end of the check valve which is
stamped with the word "OUT".
Trim the remaining flexible tubing to the desired length and connect the 4" airstone(s).
The airstones are self-weighted and will sink to the bottom when placed in the pond.
Avoid kinks and tight turns in the tubing run and take care to never fully close off the
pump outlet. Ensure that the pump can discharge sufficient air at all times,
otherwise the pump will overheat leading to diaphragm failure.
Service & Maintenance
Dust and debris blocking the air intake may cause abnormal
noises or result in a failure of the pump. Periodic cleaning
of the air intake and sponge is recommended:
• Unplug the air pump before cleaning or replacing
the air intake sponge.
• Remove the air intake cover. Remove intake filter and clean
with mild detergent.
• Rinse the components thoroughly and allow to dry completely
before reinstalling.
Air Intake Cover
Air Intake
Filter Sponge
Top Cover
Housing
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ta800Takit0400Takit0800Takito400Takito800

Tabla de contenido