CAUTION
33 : Risk of damage—Brake components will wear out quickly if the operator
misuses it to stop the machine during automatic operation.
• During operation, always permit the cylinder to stop automatically.
Note 2: In automatic operation, the drive motor, inverter, and resistors stop the cylinder. If the cylinder
does not stop in the correct length of time, an error message occurs. If this condition continues, repairs
are necessary. Speak to your dealer or Milnor. This is not routine maintenance.
Figure 21: Example of Disk Brake. Your machine can look different.
1.
Correct fluid level. You can add fluid to this level when the brake is applied or not applied.
.
Views of Brake Assembly and Reservoir
Legend
— End of BIUUUM09 —
41
Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION