Party/lock-out function
21
Party/lock-out function
●
The party/lock-out function can only be activated in
combination with the flush-type inserts 6411 U/x-101
and the control elements 6430-xx.
●
This function excludes the flush-type insert from a
group-controlled unit. That means that signals received
via the extension unit inputs and on-site operation are
ignored.
●
The function can only be activated in the upper limit
position (observe relay time of 3min.). Press the UP
key to activate for > 5 s. As acknowledgement, the
shutter is moved down for two seconds and then back
up to the upper limit position.
●
The function is deactivated by pressing the DOWN key
for > 5 sec. The shutter moves down as
acknowledgement. Deactivation is performed
automatically after approx. 8 hours.
●
Activating the party switch deactivates the sun
protection, nightfall or sun-blind function. The party
switch cannot be activated in Central and
Programming operating modes.