Step 5 Underfloor Installation Only - Securing The Flues
Push on the ends of the flues with the blue adaptor to the pipes on the underside of the Space Heater ensuring they
are fully pushed on, and secure with supplied hose clips.
Flue
Flue
Step 6 Internal and Underfloor Installation - Mounting The Flues
When mounting the combustion inlet flue and exhaust flue, they must run downwards from the Space Heater to their
open end to allow any condensation to drain out. The open ends must be angled downwards to prevent rain from
entering. Care must be taken to route exhaust flues around chassis members, avoiding gas pipes and wires.
The flues must otherwise be kept as straight as possible.
Please note: The exhaust flue must be positioned at the side or the rear end of the vehicle. The open end of the
combustion air flue must be at least 500mm away from the open end of the exhaust flue and pointing in the same
direction.
The combustion air inlet flue is attached to the underside of the floor with two of the brackets supplied. The remaining
brackets supplied with the flue kit are used to attach the exhaust flue. Clip the bracket around the flue and use two
screws (No.8 x ¾") to attach each bracket to the floor as per Fig.17.
Step 7 Internal and Underfloor Installation - Connect to Gas Supply
The appliance must be installed by a competent person in accordance with the installation instructions and comply
with any relevant regulations in the country where the appliance is installed.
The Space Heater is supplied with a compression nut and olive for 8mm (
checked and be free from dirt or other particles before connection to the compression joint on the Space Heater. The
supply pipe must be routed so that the appliance can be removed for servicing.
A gas shut-off valve must be located in the vicinity of the Space Heater and all connections must be kept to a
minimum.
A Gas Pressure Test Point must be fitted to the inlet of the appliance.
When the gas line is complete, all joints must be tested for leaks using Leak Detection Solution.
N.B. Never with a naked flame.
Fig. 16 Attaching the Flues
Screw Hole
Bracket
Fig. 17 Securing the Flue Brackets
Combustion Air Inlet
Hose Clip
Exhaust Outlet
Screw Hole
5
") pipe. The supply pipe must be
1 6
12
Hose Clip
Gas In
Space Heater
Flue

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sh2212b

Tabla de contenido