CAS2B - CAS3
CHARACTERISTICS
Transformer Power Supply
Control Unit power supply
Electric motor power supply
Motor output
Motor current
Max thrust
Weight of operator
Weight of complete unit
Operating temperature
Limit stop
Operating frequency
Opening/closing time
Max. Trolley travel (Guide Length 3000 mm)
Traction
Max height up-and-over door
Max height sectional door
Max door width
Emergency release
Guide length
Pagina 2 di 10
Technical specifications
Dimensions
CAS2B - 60Kg
230 VAC – 50/60Hz
24VDC
24VDC
65W
0,7A
600N
6 Kg
14 Kg
-25/+55 C°
Electromechanical (Avail. with Encoder)
70%
0,07 m/sec
2700 mm
Chain (Belt Version Optional)
2700 mm
2700 mm
3000 mm
Inside/Outside
3000 mm ( 2x1500 )
CAS3 - 120Kg
120W
1,2A
1200N
8 Kg
16 Kg
2700 mm
4500 mm
Rev. 05 del 19/2/2009