Petsafe stubborn dog in-ground fence Manual De Adiestramiento Y Funcionamiento página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Turn the power OFF to the outlet that the Surge Protector
and Fence Transmitter will be plugged into.
2. We recommend that, if possible, use the outlet center
screw that holds the cover plate in place to secure the
Surge Protector to the outlet. To do this, tape the top of
the cover plate to the wall, then remove the cover plate
center screw. Plug the Surge Protector into the lower outlet
and then secure the cover plate using the longer screw
included with the protector. The screw is for mechanical
attachment only and does not ground the protector.
Remove the tape and turn ON the power to the outlet.
3. Run the Boundary Wire through a window, under a door,
through a crawl space vent, or any other appropriate
available access. You can also drill a hole through your wall.
4. Strip
inch of insulation from the ends of the Boundary Wire. Insert the stripped
3
8
ends into the 2 left red connector holes on the bottom of the Surge Protector labeled
"Loop" (4B). There should be 1 wire in each connector hole. Press the plastic tab,
insert the wires and release the tab. Make sure the wires do not touch each
other at the terminals.
NOTICE
5. Determine the length of wire needed to pass from the Surge Protector to the Fence
Transmitter. Measure and cut 2 lengths of wire, then strip
ends. Twist the 2 lengths together, with at least 10-12 twists per foot, so the wires will
not send out a signal.
6. Insert the ends of the the twisted transmitter wires into the right 2 black connectors at the bottom
of the Surge Protector labeled "Transmitter".
7. Press the red plastic tabs on the Fence Transmitter and insert the opposite ends of the twisted wire into the
Boundary Wire Terminals.
8. Turn the Boundary Width Control knob to 10. This will set the Boundary Width at the maximum width.
9. Plug in the transmitter power adapter to the outlet on the front of the Surge Protector.
10. The Power Light and Loop Indicator Lights should come on. If this does not happen,
see the "Troubleshooting" section.
NOTICE
Verify that the boundary loop and transmitter wires connect to the proper Surge Protector
terminals. Reversed connections will result in an increased risk of surge related damage.
For added protection, when unused for long periods of time or prior to thunderstorms, unplug from the wall outlet and disconnect
the loop boundary wires. This will prevent damage to the transmitter due to surges.
www.petsafe.net
4A
Loop
Transmitter
LP-4100
Red Loop Tabs
Boundary Wires
(Twisted)
Boundary Wire
Loop
inch of insulation at both
3
8
Fence Transmitter
Power
Adapter
Boundary
Power
Wire
Jack
Terminals
Black
Transmitter
Tabs
Transmitter
Wires
(Twisted)
4B
Push Tab
Down
Insert bare end
of wire into
opened slot
and release tab
to lock.
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hig11-11052

Tabla de contenido