Firing Schedule for VINTAGE
Firing of Powder Opaque I
Firing of Powder Opaque II 650
Firing of Paste Opaque I
Firing of Paste Opaque II
Firing of Body,
Opaque-Dentine, Incisal
and Translucent, 1. firing
Firing of Body,
Opaque-Dentine, Incisal
and Translucent, 2. firing
Self-glazing
Firing of correction
(Add-On Porcelain)
Firing of gingiva
VINTAGE Porcelain
(pink, dark pink)
The above-mentioned is to be understood as a recommended guideline
english
Pre-
Drying
Vacuum Incr. tem- Vacuum
heating
(min)
(°C)
650
3
3
450
6
450
6
650
5
650
5
650
3-5
650
3-5
650
3-5
18
Porcelain System
perature final tem-
(°C/min) perature perature
full
60
950
full
60
940
full
60
950
full
60
940
full
60
910
full
60
905
0
60
0
full
60
870
full
60
870
Final
Holding
tem-
time
(min)
950
1
940
1
950
1
940
1
910
0
905
0
900
0,5
870
0
870
0